According to the British Safety Industry Federation (BSIF), recent UK research suggests that up to 50% of all the Respiratory Protective Equipment (RPE) used does not offer adequate protection to the wearer.
Inadequate face fit testing (for workers requiring close-fit masks), results in leaks due to poor fit. This is a major cause of exposure to harmful dust, that is ultimately hazardous to health.
Those responsible for managing health and safety, or procuring services requiring RPE must ensure face fit testing has been conducted.
This includes that the testing is up-to-date and that the correct RPE is being used; that is both adequate for the project and suitable for the wearer.
Depending on the type of work being conducted, employees identified (through risk assessments) as being at risk of exposure to hazardous dust or other respirable substances must wear suitable face-fit tested RPE.
Ensuring your teams and contractors are provided with (and using) Respiratory Protective Equipment (RPE) correctly is a key step to safeguard from occupational related respiratory diseases such as Asbestosis and Silicosis.
To prevent exposure to dust, the Control of Substances Hazardous to Health (COSHH), the Control of Lead at Work (CLaW), Ionising Radiation Regulations 2017 (IRR17), the Control of Asbestos Regulations 2012 (CAR 2012), and other related Associated Codes of Practice Guidance (ACOP), require that RPE is correctly selected. In addition, many types of RPE (tight-fitting face pieces), must undergo adequate face fit testing for each individual wearer where harmful substances may be present. Face fit testing must also be carried out by a competent person with adequate knowledge, instruction, and training in conducting Face Fit testing.
Providing RPE to your employees, or ensuring your contractors are providing the correct RPE to their teams, is one step in the line of protection against occupational respiratory diseases. It is important to emphasise that RPE is only effective when the wearer uses RPE correctly and the RPE is maintained.
According to the HSG53, RPE at work should:
There are two types of face fit testing; Qualitative (subjective) and Quantitative (measurable) testing. The type of testing required is dependant upon the environment in which the RPE (Respiratory Protective Equipment) will be used and the type of RPE.
Qualitative testing is subjective as it relies upon the wearer’s sense of taste. The mask wearer will wear a ‘loose-fitting hood’ firstly without a mask and the tester sprays a distinctive tasting solution into the hood. The wearer then indicates when they taste the solution.
The mask wearer then wears both the mask and the hood and the taste test is repeated. At this stage, the RPE filter will be removing the solution from the inhaled air. If at any point the wearer can taste the solution then the test is stopped as air is entering the mask from another location, other than the filter. The mask on the user will be checked to see if the breach is due to the way the mask is worn or a different make or model solves the issue. If the test is completed with no solution tasted then the test is passed.
Quantitative testing relies on particle counting to determine the effectiveness of the face fit seal as opposed to relying on the individual wearer. During the test, a particle generator releases particles into the test room. There are particle counters both in the room and in the mask. The number of particles that enter the mask during this time are measured by a machine determining the mask’s effectiveness.
During an inspection by the HSE (Guidance HSE INDG479), auditors will check that:
Whilst providing RPE as a suitable control measure to prevent unnecessary exposures that can affect employees lungs, it is important to assess all the risks that may be present (including possible unforeseen risks) in the space your employees and contractors are working and consider further control measures and engineered controls to minimise the risks of exposure.
From this risk assessment, you can then collate your Occupational Health and Safety Management System (ISO 45001: 2018), detailing the actions required to control the risks. This should include methods of prevention, a list of PPE and RPE required and review and assessment dates to assess if the plan is effective in prevent exposure to potentially deadly dust.
Ensuring Respiratory Protective Equipment (RPE) is effectively used is imperative to protection. Integrating RPE with standard operational procedures along with other control measures, and ensuring adequate training is provided for RPE users negates improper and ineffective use of RPE.
Conducting Face Fit Testing in conjunction with COSHH Awareness training courses regarding harmful substances can help the employees understand how to correctly use their RPE and assist you as an employer to ensure health and safety practices are enforced by the individual.
British Safety Industry Federation: https://www.bsif.co.uk/
HSE Respiratory Protective Equipment Website: http://www.hse.gov.uk/respiratory-protective-equipment/
Control Of Substance Hazardous To Health Services: https://www.lucionservices.com/services/coshh-compliance/
HSE Control Of Lead At Work: http://www.hse.gov.uk/lead/
HSE Control Of Asbestos Regulations: http://www.hse.gov.uk/asbestos/regulations.htm
COSHH Awareness Training: https://www.lucionservices.com/training-courses/coshh-awareness/
Lucion Consulting: https://www.lucionservices.com/companies/lucion-consulting/
Lucion Consulting Training Courses: https://www.lucionservices.com/companies/lucion-training/
Qualitative Face Fit Testing – Lucion Consulting: https://www.lucionservices.com/training-course-categories/health-and-safety/
HSE Operational Circular 282/28: http://www.hse.gov.uk/foi/internalops/ocs/200-299/282_28.pdf
Occupational Health And Safety Management System (ISO 45001: 2018): https://www.lucionservices.com/services/iso-45001-2018/
Respiratory Protective Equipment At Work HSG53 (2013): http://www.hse.gov.uk/pubns/priced/hsg53.pdf
Asbestos Exposure Assessments – Specialist Consultants: https://www.lucionservices.com/services/asbestos-exposure-assessments/
Protect Your Team: Managing The Workplace Exposure Risk: https://www.lucionservices.com/work-place-exposure-limits-update-coshh/
Top Of The Charts: Lucion Consulting Named Best Training Provider In UK: https://www.lucionservices.com/lucion-consulting-named-best-training-provider-in-the-uk/
Lucion Consulting Health And Safety Course: https://www.lucionservices.com/training-course-categories/health-and-safety/
Don’t miss a beat - get the latest insights and updates from Lucion straight to your inbox.